Skip to content
FiftyCalc Free calculators for all 50 states

Activation Energy Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

Enter the rate constant at two temperatures; the two-point Arrhenius equation gives the activation energy.

Result

Sample figures

Activation energy Ea (kJ/mol)—

Pre-exponential factor A (unit of k) —

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Activation Energy Calculator

Rate constant k₁ (any unit, same for both): enter 0 or more. Prefilled example: 0.0025.

Temperature T₁, in °C: enter -273.15 or more. Prefilled example: 25.

Rate constant k₂ (same unit as k₁): enter 0 or more. Prefilled example: 0.01.

Temperature T₂, in °C: enter -273.15 or more. Prefilled example: 45.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Rate constant k₁ (any unit, same for both): enter 0 or more.
  2. Temperature T₁, in °C: enter -273.15 or more.
  3. Rate constant k₂ (same unit as k₁): enter 0 or more.
  4. Temperature T₂, in °C: enter -273.15 or more.
  5. Read the result: Activation energy Ea (kJ/mol); the panel also shows Pre-exponential factor A (unit of k).

How this calculator works

Two-point form of the Arrhenius equation: ln(k₂ / k₁) = (Ea / R) × (1/T₁ − 1/T₂), so Ea = R × ln(k₂ / k₁) ÷ (1/T₁ − 1/T₂), with temperatures in kelvin (K = °C + 273.15).

Then A = k₁ × e^(Ea / (R T₁)). R = N_A × k = 8.314462618 J/(mol·K), from the exact Avogadro and Boltzmann constants (CODATA 2022 values from NIST (physics.nist.gov/cuu/Constants, read 2026-10-27)).

The formula

  1. Ea=8.31446261815324×ln⁡(k2k1)÷(1÷(t1+273.15)−1÷(t2+273.15))1,000
Symbols used in the formula
SymbolMeaningUnit
k1Rate constant k₁ (same for both)any unit
t1Temperature T₁°C
k2Rate constant k₂ (same unit as k₁)
t2Temperature T₂°C
EaActivation energy EakJ/mol

Worked example

Rate constant k₁ (any unit, same for both)0.0025
Temperature T₁25 °C
Rate constant k₂ (same unit as k₁)0.01
Temperature T₂45 °C
Pre-exponential factor A (unit of k)9,445,160.0326
  1. Ea=8.31446261815324×ln⁡(0.010.0025)÷(1÷(25+273.15)−1÷(45+273.15))1,000=54.6671

Activation energy Ea (kJ/mol) 54.67

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

What does activation energy mean?

It is the minimum energy colliding molecules need for the reaction to happen. A higher Ea means the rate rises faster with temperature.

Why must temperatures be in kelvin?

The Arrhenius equation uses absolute temperature; the calculator adds 273.15 to your Celsius values.

What if k₂ is smaller than k₁ at the higher temperature?

Ea comes out negative, which usually points to a measurement problem or a multi-step mechanism.