MLVSS Calculator
Test cases replayed : 2 of 2 match · Methodology · No outside source listed
Enter the filter weights from your solids test to get mixed liquor suspended solids and volatile suspended solids.
Result
MLVSSmg/L
MLSS (mg/L)
- Volatile fraction (MLVSS ÷ MLSS)
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Filter and dish, before use (g): enter 0 or more.
- After drying at 103-105 °C (g): enter 0 or more.
- After ignition at 550 °C (g): enter 0 or more.
- Sample volume filtered, in mL: enter 0.1 or more.
- Read the result: MLVSS; the panel also shows MLSS (mg/L) and Volatile fraction (MLVSS ÷ MLSS).
How this calculator works
Total suspended solids (mg/L) = (weight after drying − tare, in g) × 1,000,000 ÷ sample mL (Standard Methods 2540 D). Volatile suspended solids (mg/L) = (weight after drying − weight after ignition) × 1,000,000 ÷ sample mL (Standard Methods 2540 E). In an activated sludge aeration tank these are the MLSS and MLVSS.
The g-to-mg conversion (× 1,000) and mL-to-L conversion (× 1,000) give the factor of 1,000,000. The volatile fraction of activated sludge is often around 70% to 80%.
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| After drying at 103-105 °C | g | |
| After ignition at 550 °C | g | |
| Sample volume filtered | mL | |
| MLVSS | mg/L |
Worked example
| Filter and dish, before use (g) | 1.5432 |
|---|---|
| After drying at 103-105 °C (g) | 1.5712 |
| After ignition at 550 °C (g) | 1.5488 |
| Sample volume filtered | 10 mL |
| MLSS (mg/L) | 2,800 |
|---|---|
| Volatile fraction (MLVSS ÷ MLSS) | 80% |
MLVSS 2,240 mg/L
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
What do the example weights give?
28 mg of solids in 10 mL is 2,800 mg/L MLSS; 22.4 mg lost on ignition is 2,240 mg/L MLVSS, an 80% volatile fraction.
Why measure MLVSS?
The volatile part approximates the organic, mostly biological, solids that treat the wastewater; it is used for the food-to-microorganism ratio.