Skip to content
FiftyCalc Free calculators for all 50 states

SiPM PDE Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

A silicon photomultiplier counts a photon only if it is absorbed, lands on an active cell and triggers an avalanche. Enter the three probabilities.

Result

Sample figures

Photon detection efficiency—

Photons detected (average) —

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

SiPM PDE Calculator

Quantum efficiency at the wavelength, in percent: enter a number from 0 to 100. Prefilled example: 80.

Geometric fill factor, in percent: enter a number from 0 to 100. Prefilled example: 60.

Avalanche trigger probability, in percent: enter a number from 0 to 100. Prefilled example: 90.

Photons reaching the sensor: enter 0 or more. Prefilled example: 1,000.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Quantum efficiency at the wavelength, in percent: enter a number from 0 to 100.
  2. Geometric fill factor, in percent: enter a number from 0 to 100.
  3. Avalanche trigger probability, in percent: enter a number from 0 to 100.
  4. Photons reaching the sensor: enter 0 or more.
  5. Read the result: Photon detection efficiency; the panel also shows Photons detected (average).

How this calculator works

PDE = QE × FF × P_trigger: QE is the probability that a photon creates an electron-hole pair, FF the share of the surface covered by active microcells and P_trigger the probability that the carrier starts a Geiger avalanche. All three are fractions.

QE depends on wavelength and P_trigger rises with overvoltage, so PDE is quoted at a given wavelength and bias. Maker data sheets usually give PDE curves directly; crosstalk and afterpulsing are not counted here.

The formula

  1. Pde=qe×ff×pt10,000
Symbols used in the formula
SymbolMeaningUnit
qeQuantum efficiency at the wavelength%
ffGeometric fill factor%
ptAvalanche trigger probability%
PdePhoton detection efficiency%

Worked example

Quantum efficiency at the wavelength80%
Geometric fill factor60%
Avalanche trigger probability90%
Photons reaching the sensor1,000
Photons detected (average)432
  1. Pde=80×60×9010,000=43.2

Photon detection efficiency 43.2%

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

Why is SiPM PDE lower than quantum efficiency?

Dead space between cells (fill factor) and avalanches that fail to start (trigger probability) both lose photons.

What PDE do QE 80%, FF 60% and trigger 90% give?

43.2%.

Related calculators