Vapor Pressure Deficit Calculator
Test cases replayed : 3 of 3 match · Methodology · No outside source listed
Enter the air temperature and relative humidity, and optionally how much cooler the leaves are, to get the air and leaf VPD in kilopascals.
Result
Air VPDkPa
Air temperature (°C)
- Saturation vapor pressure at air temperature (kPa)
- Actual vapor pressure (kPa)
- Leaf temperature (°C)
- Leaf VPD (kPa)
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
Affiliate link
This is an affiliate link. As an Amazon Associate I earn from qualifying purchases. This does not change the result.
Search Amazon for digital hygrometers. Visit Amazon
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Temperature unit: choose °F or °C.
- Air temperature: enter a number.
- Relative humidity, in percent: enter a number from 0 to 100.
- Leaf temperature minus air temperature (e.g. -3.6 °F; 0 if unknown), in °: enter a number.
- Read the result: Air VPD; the panel also shows Air temperature (°C), Saturation vapor pressure at air temperature (kPa), Actual vapor pressure (kPa), Leaf temperature (°C) and Leaf VPD (kPa).
How this calculator works
Saturation vapor pressure e°(T) = 0.6108 × exp(17.27 T ÷ (T + 237.3)) kPa, T in °C (FAO Irrigation and Drainage Paper 56, chapter 3, equation 11). Actual vapor pressure eₐ = e°(T) × RH ÷ 100 (equation 19). VPD = e° − eₐ. Source: FAO, "Crop evapotranspiration", https://www.fao.org/4/x0490e/x0490e07.htm, read 2026-10-27.
Leaf VPD uses the saturation pressure at leaf temperature minus the air's actual vapor pressure; leaves are often a little cooler than the air. °F is converted with °C = (°F − 32) ÷ 1.8.
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| Temperature unit (1: °F; 0: °C) | ||
| Air temperature | ||
| Relative humidity | % | |
| Air temperature | °C | |
| Saturation vapor pressure at air temperature | kPa | |
| Actual vapor pressure | kPa | |
| Air VPD | kPa |
Worked example
| Temperature unit | °F |
|---|---|
| Air temperature | 77 |
| Relative humidity | 60% |
| Leaf temperature minus air temperature (e.g. -3.6 °F; 0 if unknown) | 0 ° |
| Saturation vapor pressure at air temperature (kPa) | 3.1678 |
|---|---|
| Actual vapor pressure (kPa) | 1.9007 |
| Leaf VPD (kPa) | 1.2671 |
Air VPD 1.2671 kPa
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
What is the VPD at 77 °F and 60% humidity?
About 1.27 kPa for the air (saturation 3.168 kPa, actual 1.901 kPa); with leaves 3.6 °F cooler the leaf VPD is about 0.91 kPa.
What does a high VPD mean?
Drier air relative to its temperature: plants lose water faster through transpiration. A low VPD means humid air and slower transpiration.