Skip to content
FiftyCalc Free calculators for all 50 states

AC Wattage Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

An air conditioner's power draw is its cooling capacity divided by its efficiency rating (EER). Enter both, plus your voltage and daily run time.

Result

Sample figures

Power draw—W

Current (amps) —

  • Energy per day (kWh)—

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

AC Wattage Calculator

Cooling capacity, in BTU/h: enter 0 or more. Prefilled example: 12,000.

Efficiency (EER or CEER, BTU/h per watt): enter 0.1 or more. Prefilled example: 10.

Supply voltage, in V: enter 1 or more. Prefilled example: 115.

Hours of use per day: enter a number from 0 to 24. Prefilled example: 8.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Cooling capacity, in BTU/h: enter 0 or more.
  2. Efficiency (EER or CEER, BTU/h per watt): enter 0.1 or more.
  3. Supply voltage, in V: enter 1 or more.
  4. Hours of use per day: enter a number from 0 to 24.
  5. Read the result: Power draw; the panel also shows Current (amps) and Energy per day (kWh).

How this calculator works

Energy Efficiency Ratio EER = cooling output (BTU/h) ÷ electrical input (W), as defined in the US Department of Energy test procedures (10 CFR 430). So the power draw is W = BTU/h ÷ EER.

Current I = W ÷ V, treating the unit as a resistive load; with a compressor motor the real current is a little higher (power factor below 1). Energy per day = W × hours ÷ 1,000.

The formula

  1. W=btueer
Symbols used in the formula
SymbolMeaningUnit
btuCooling capacityBTU/h
eerEfficiency (EER or CEER, BTU/h per watt)
WPower drawW

Worked example

Cooling capacity12,000 BTU/h
Efficiency (EER or CEER, BTU/h per watt)10
Supply voltage115 V
Hours of use per day8
Current (amps)10.4348
Energy per day (kWh)9.6
  1. W=12,00010=1,200

Power draw 1,200 W

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

How many watts does a 12,000 BTU air conditioner use?

At an EER of 10, about 1,200 W while the compressor runs.

Does a higher EER save energy?

Yes. The same cooling with a higher EER takes fewer watts.

Questions answered

Related calculators