Skip to content
FiftyCalc Free calculators for all 50 states

Battery Size Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

Find the battery capacity needed to run a load for a given time, allowing for depth of discharge and inverter losses.

Result

Sample figures

Battery capacity needed (Ah)—

Battery energy needed (Wh) —

  • Battery energy needed (kWh)—

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Battery Size Calculator

Load, in W: enter 0 or more. Prefilled example: 500.

Hours of use: enter 0 or more. Prefilled example: 4.

Battery bank voltage, in V: enter 0.1 or more. Prefilled example: 12.

Allowed depth of discharge, in percent: enter a number from 1 to 100. Prefilled example: 50.

Inverter efficiency, in percent: enter a number from 1 to 100. Prefilled example: 90.

Affiliate link

This is an affiliate link: FiftyCalc may earn a commission if you buy through it. This does not change the result.

Tenergy sells rechargeable batteries and battery chargers. Visit Tenergy

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Load, in W: enter 0 or more.
  2. Hours of use: enter 0 or more.
  3. Battery bank voltage, in V: enter 0.1 or more.
  4. Allowed depth of discharge, in percent: enter a number from 1 to 100.
  5. Inverter efficiency, in percent: enter a number from 1 to 100.
  6. Read the result: Battery capacity needed (Ah); the panel also shows Battery energy needed (Wh) and Battery energy needed (kWh).

How this calculator works

Energy needed = load (W) × hours ÷ depth of discharge ÷ inverter efficiency; capacity (Ah) = energy ÷ bank voltage.

Lead-acid batteries are commonly limited to about 50% depth of discharge for long life, while lithium iron phosphate (LiFePO4) batteries are often used to 80% or more; check the maker's rating. Use 100% inverter efficiency for a DC load.

The formula

  1. Wh=w×h÷(dod÷100)eff÷100
  2. Ah=Whv
Symbols used in the formula
SymbolMeaningUnit
wLoadW
hHours of use
vBattery bank voltageV
dodAllowed depth of discharge%
effInverter efficiency%
WhBattery energy neededWh
AhBattery capacity neededAh

Worked example

Load500 W
Hours of use4
Battery bank voltage12 V
Allowed depth of discharge50%
Inverter efficiency90%
Battery energy needed (Wh)4,444.4444
Battery energy needed (kWh)4.4444
  1. Wh=500×4÷(50÷100)90÷100=4,444.44
  2. Ah=4,444.4412=370.37

Battery capacity needed (Ah) 370.3704

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.