Buckling Calculator
Test cases replayed : 3 of 3 match · Methodology · No outside source listed
A long, slender column fails by bowing sideways well before the material crushes. Enter the material stiffness, the section's second moment of area, the length and how the ends are held.
Result
Critical loadkN
Critical load (lbf)
- Effective length KL (m)
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Young's modulus E, in GPa: enter 0 or more.
- Second moment of area I, weak axis (mm⁴): enter 0 or more.
- Column length L, in m: enter 0.01 or more.
- End conditions (effective length factor K): choose Pinned–pinned (K = 1), Fixed–fixed (K = 0.5), Fixed–pinned (K = 0.7) or Fixed–free, flagpole (K = 2).
- Read the result: Critical load; the panel also shows Critical load (lbf) and Effective length KL (m).
How this calculator works
Euler's formula: Pcr = π² E I ÷ (K L)², with E the modulus of elasticity, I the smallest second moment of area of the section, L the unbraced length and K the effective-length factor for the end conditions (theoretical values 1, 0.5, 0.7 and 2).
It applies to slender, elastic columns. Short or intermediate columns yield first; design codes such as the AISC Specification then use inelastic column curves and safety factors, which this calculator does not apply.
1 lbf = 4.4482216152605 N, exact by definition (NIST SP 811, Appendix B (nist.gov/pml/special-publication-811, read 2026-10-27)).
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| Young's modulus E | GPa | |
| Second moment of area I, weak axis (mm⁴) | ||
| Column length L | m | |
| End conditions (effective length factor K) | ||
| Critical load | kN |
Worked example
| Young's modulus E | 200 GPa |
|---|---|
| Second moment of area I, weak axis (mm⁴) | 1,000,000 |
| Column length L | 3 m |
| End conditions (effective length factor K) | Pinned–pinned (K = 1) |
| Critical load (lbf) | 49,306 |
|---|---|
| Effective length KL (m) | 3 |
Critical load 219.3245 kN
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
Why use the weak axis?
A column buckles about the axis with the smallest second moment of area, so that I gives the lowest, governing load.
How does length change the buckling load?
The load falls with the square of the length: doubling L cuts the critical load to a quarter.