Chemical Oxygen Demand Calculator
Test cases replayed : 2 of 2 match · Methodology · No outside source listed
Enter the ferrous ammonium sulfate (FAS) volumes for the blank and the sample, its normality and the sample volume.
Result
Chemical oxygen demand (mg/L O₂)
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- FAS for the blank, A, in mL: enter 0 or more.
- FAS for the sample, B, in mL: enter 0 or more.
- FAS normality C (N): enter 0 or more.
- Sample volume, in mL: enter 0 or more.
- Chloride correction D from your curve (0 if none), in mg/L: enter 0 or more.
- Sample type: choose Fresh water (no saline factor) or Saline water, EPA 410.3 factor 1.2.
- Read the result: Chemical oxygen demand (mg/L O₂).
How this calculator works
COD (mg/L) = [(A − B) × C × 8,000 − 50 × D] ÷ mL of sample × 1.2, as written in EPA Method 410.3 (titrimetric, high level for saline waters), section 8.0 (epa.gov method_410-3_1978.pdf, read 2026-10-27). A and B are mL of ferrous ammonium sulfate for the blank and the sample, C its normality, D the chloride correction.
For fresh water with no chloride correction, set D = 0 and leave out the 1.2 factor: COD = (A − B) × C × 8,000 ÷ mL of sample. The 8,000 is the equivalent weight of oxygen (8 g) × 1,000 mg/g.
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| FAS for the blank, A | mL | |
| FAS for the sample, B | mL | |
| FAS normality C (N) | ||
| Sample volume | mL | |
| Chloride correction D from your curve (0 if none) | mg/L | |
| Sample type | ||
| Chemical oxygen demand (mg/L O₂) |
Worked example
| FAS for the blank, A | 24.5 mL |
|---|---|
| FAS for the sample, B | 18.3 mL |
| FAS normality C (N) | 0.25 |
| Sample volume | 50 mL |
| Chloride correction D from your curve (0 if none) | 0 mg/L |
| Sample type | Fresh water (no saline factor) |
Chemical oxygen demand (mg/L O₂) 248.0
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
Why is the blank titration larger?
Organic matter in the sample uses up dichromate, so less is left to titrate; the difference measures the oxygen demand.
Is COD the same as BOD?
No. COD oxidizes nearly all organic matter chemically in a few hours; BOD measures what microbes consume over five days.