Electric Heater Size Calculator
Test cases replayed : 3 of 3 match · Methodology · No outside source listed
Enter the heat loss of the room at the coldest design temperature, the circuit voltage and the wattage of the heaters you are considering.
Result
Heater capacity neededW
Heater capacity needed (kW)
- Current at full output (amps)
- Number of heaters of that wattage
- Cost per hour at full output
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
Affiliate link
This is an affiliate link. As an Amazon Associate I earn from qualifying purchases. This does not change the result.
Search Amazon for electric space heaters. Visit Amazon
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Room heat loss at design temperature, in BTU/h: enter 0 or more.
- Circuit voltage (V): choose 120 V, 208 V or 240 V.
- Wattage of one heater, in W: enter 1 or more.
- Electricity price, in dollars / kWh: enter 0 or more.
- Read the result: Heater capacity needed; the panel also shows Heater capacity needed (kW), Current at full output (amps), Number of heaters of that wattage and Cost per hour at full output.
How this calculator works
An electric resistance heater turns all of the electricity it draws into heat, so its output in BTU per hour = watts × 3.412. Watts needed = heat loss ÷ 3.412, using the EIA conversion factor 1 kWh = 3,412 Btu.
Current (amps) = watts ÷ volts (P = V × I for a resistive load). Number of heaters = watts needed ÷ wattage of one heater, rounded up. Cost per hour at full output = kW × price per kWh; a thermostat runs the heater only part of the time, so the real cost per hour is lower in mild weather.
The room's heat loss can be estimated with the Heat Loss calculator from wall, window and ceiling areas, insulation and air leakage.
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| Room heat loss at design temperature | BTU/h | |
| Heater capacity needed | W |
Worked example
| Room heat loss at design temperature | 5,000 BTU/h |
|---|---|
| Circuit voltage (V) | 240 V |
| Wattage of one heater | 1,500 W |
| Electricity price | $0.17 / kWh |
| Heater capacity needed (kW) | 1.47 |
|---|---|
| Current at full output (amps) | 6.1 |
| Number of heaters of that wattage | 1 |
| Cost per hour at full output | $0.25 |
Heater capacity needed 1,465 W
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
How many watts does it take to heat a room?
As many as the room loses at the coldest expected temperature. A well-insulated room loses much less than a drafty one of the same size, so start from its heat loss rather than from floor area alone.
Should I use 120 V or 240 V?
Large baseboard and wall heaters usually run on 240 V, which draws half the current of 120 V for the same power. Wire size and breaker must match the circuit's current under the electrical code; have a licensed electrician size the circuit.
Is a 1,500 W heater enough?
A 1,500 W heater delivers about 5,118 BTU per hour (1,500 × 3.412). It is enough if the room's heat loss at design temperature is below that.