Langelier Saturation Index Calculator
Test cases replayed : 3 of 3 match · Methodology · No outside source listed
Enter the test results of your water. The calculator gives the pH at which the water is just saturated with calcium carbonate, the Langelier index (scale-forming or corrosive tendency) and the Ryznar index.
Result
Langelier Saturation Index, LSI
Tendency of the water
- Saturation pH, pHs
- Ryznar Stability Index, RSI
- Temperature used (°C)
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Measured pH: enter a number from 0 to 14.
- Water temperature: enter a number.
- Temperature unit: choose °F or °C.
- Calcium hardness (mg/L or ppm as CaCO₃): enter 0.01 or more.
- Alkalinity (mg/L or ppm as CaCO₃): enter 0.01 or more.
- Total dissolved solids, TDS (mg/L or ppm): enter 0.01 or more.
- Read the result: Langelier Saturation Index, LSI; the panel also shows Tendency of the water, Saturation pH, pHs, Ryznar Stability Index, RSI and Temperature used (°C).
How this calculator works
LSI = pH − pHs, with pHs = 9.3 + A + B − C − D, where A = (log₁₀ TDS − 1) ÷ 10, B = −13.12 × log₁₀(°C + 273) + 34.55, C = log₁₀(calcium hardness as CaCO₃) − 0.4 and D = log₁₀(alkalinity as CaCO₃), all in mg/L.
Ryznar Stability Index RSI = 2 pHs − pH. Formulas and readings (LSI > 0 tends to precipitate, 0 equilibrium, < 0 tends to corrode) as given in Table 1 of García-Ávila et al., Data in Brief 18 (2018), doi 10.1016/j.dib.2018.03.007 (PMC5996164), read on Europe PMC on October 28, 2026.
Temperatures in °F are converted with °C = (°F − 32) × 5 ÷ 9. The LSI is shown to two decimals and its sign gives the reading.
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| Measured pH | ||
| Water temperature | ||
| Calcium hardness (mg/L or ppm as CaCO₃) | ||
| Alkalinity (mg/L or ppm as CaCO₃) | ||
| Total dissolved solids, TDS | mg/L or ppm | |
| One if Temperature unit is °F, zero otherwise | ||
| Result of step 1 | ||
| Result of step 2 | ||
| Result of step 3 | ||
| Result of step 4 | ||
| Result of step 5 | ||
| Result of step 6 | ||
| Langelier Saturation Index, LSI |
Worked example
| Measured pH | 7.5 |
|---|---|
| Water temperature | 80 |
| Temperature unit | °F |
| Calcium hardness (mg/L or ppm as CaCO₃) | 300 |
| Alkalinity (mg/L or ppm as CaCO₃) | 100 |
| Total dissolved solids, TDS (mg/L or ppm) | 1,000 |
| Tendency of the water | Positive LSI — the water tends to deposit calcium carbonate (scale-forming) |
|---|---|
| Saturation pH, pHs | 7.48 |
| Ryznar Stability Index, RSI | 7.46 |
| Temperature used (°C) | 26.7 |
Langelier Saturation Index, LSI 0.02
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
Is this the same as the saturation index on my pool test kit?
It measures the same tendency, but a test kit or pool controller may use its maker's own method, so compare readings made with the same method. Follow the maker's instructions for which alkalinity to enter.
How do I read the Ryznar index?
It uses the same pHs. In the same Table 1: below 5.5 highly scale-forming, 5.5 to 6.2 relatively scale-forming, 6.2 to 6.8 balanced, 6.8 to 8 low corrosion, above 8 high corrosion.
What makes the LSI go up?
A higher pH raises the LSI directly; a higher temperature, calcium hardness or alkalinity lowers pHs and so raises the LSI; more dissolved solids raise pHs slightly and lower the LSI.