Off-Grid Solar Calculator
Test cases replayed : 2 of 2 match · Methodology · No outside source listed
Start from the energy you use per day, then size the solar array that refills it and the battery bank that carries you through cloudy days.
Result
Number of panels
Solar array needed (W)
- Battery bank, nominal (kWh)
- Battery bank at that voltage (Ah)
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
Affiliate link
This is an affiliate link: FiftyCalc may earn a commission if you buy through it. This does not change the result.
ALLPOWERS sells portable power stations and portable solar panels. Visit ALLPOWERS
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Daily energy use (Wh per day): enter 0 or more.
- Peak sun hours at your site (hours per day): enter a number from 0.5 to 12.
- System derate, share of panel rating delivered, in percent: enter a number from 1 to 100.
- Panel rating (W): enter 1 or more.
- Days of autonomy, in days: enter a number from 0 to 14.
- Usable depth of discharge of the battery, in percent: enter a number from 1 to 100.
- Inverter and battery round-trip efficiency, in percent: enter a number from 1 to 100.
- Battery bank voltage (V): choose 12 V, 24 V or 48 V.
- Read the result: Number of panels; the panel also shows Solar array needed (W), Battery bank, nominal (kWh) and Battery bank at that voltage (Ah).
How this calculator works
Energy balance: the array must replace each day's use on the sun of one day. Array watts = daily Wh ÷ (peak sun hours × derate). Panels = array watts ÷ panel rating, rounded up.
Peak sun hours equal the solar energy reaching the panels in kWh per square meter per day. For year-round off-grid use, take the lowest month for your site and tilt; the PVWatts calculator of the National Laboratory of the Rockies, a U.S. Department of Energy laboratory (pvwatts.nlr.gov), gives monthly solar radiation values for a chosen location.
Battery bank (kWh) = daily Wh × days of autonomy ÷ usable depth of discharge ÷ efficiency ÷ 1,000. Amp-hours = battery Wh ÷ bank voltage.
The derate covers wiring, temperature, soiling and charge-controller losses, and also the inverter and battery losses, because the array formula does not divide by the efficiency entered for the battery bank; enter the figure from your system designer. The result is a first sizing, not a wiring or code design.
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| Daily energy use | Wh per day | |
| Peak sun hours at your site | hours per day | |
| System derate, share of panel rating delivered | % | |
| Panel rating | W | |
| Solar array needed | W | |
| Number of panels | ||
ceil(x) | the smallest whole number not below x. |
Worked example
| Daily energy use (Wh per day) | 3,000 |
|---|---|
| Peak sun hours at your site (hours per day) | 4.5 |
| System derate, share of panel rating delivered | 75% |
| Panel rating (W) | 400 |
| Days of autonomy | 2 days |
| Usable depth of discharge of the battery | 50% |
| Inverter and battery round-trip efficiency | 90% |
| Battery bank voltage (V) | 24 V |
| Solar array needed (W) | 889 |
|---|---|
| Battery bank, nominal (kWh) | 13.33 |
| Battery bank at that voltage (Ah) | 556 |
Number of panels 3
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
What depth of discharge should I enter?
Use the usable share your battery maker allows for the cycle life you want. It is printed in the battery datasheet or warranty.
Why does a higher voltage give fewer amp-hours?
The stored energy is the same; amp-hours are energy divided by voltage, so a 48 V bank needs half the amp-hours of a 24 V bank.
Does this include a backup generator?
No. The array and batteries are sized to cover the load alone; a generator lets you choose fewer days of autonomy.