Skip to content
FiftyCalc Free calculators for all 50 states

Off-Grid Solar Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

Start from the energy you use per day, then size the solar array that refills it and the battery bank that carries you through cloudy days.

Result

Sample figures

Number of panels—

Solar array needed (W) —

  • Battery bank, nominal (kWh)—
  • Battery bank at that voltage (Ah)—

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Off-Grid Solar Calculator

Daily energy use (Wh per day): enter 0 or more. Prefilled example: 3,000.

Peak sun hours at your site (hours per day): enter a number from 0.5 to 12. Prefilled example: 4.5.

System derate, share of panel rating delivered, in percent: enter a number from 1 to 100. Prefilled example: 75.

Panel rating (W): enter 1 or more. Prefilled example: 400.

Days of autonomy, in days: enter a number from 0 to 14. Prefilled example: 2.

Usable depth of discharge of the battery, in percent: enter a number from 1 to 100. Prefilled example: 50.

Inverter and battery round-trip efficiency, in percent: enter a number from 1 to 100. Prefilled example: 90.

Battery bank voltage (V)

Battery bank voltage (V): choose 12 V, 24 V or 48 V. Prefilled example: 24 V.

Affiliate link

This is an affiliate link: FiftyCalc may earn a commission if you buy through it. This does not change the result.

ALLPOWERS sells portable power stations and portable solar panels. Visit ALLPOWERS

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Daily energy use (Wh per day): enter 0 or more.
  2. Peak sun hours at your site (hours per day): enter a number from 0.5 to 12.
  3. System derate, share of panel rating delivered, in percent: enter a number from 1 to 100.
  4. Panel rating (W): enter 1 or more.
  5. Days of autonomy, in days: enter a number from 0 to 14.
  6. Usable depth of discharge of the battery, in percent: enter a number from 1 to 100.
  7. Inverter and battery round-trip efficiency, in percent: enter a number from 1 to 100.
  8. Battery bank voltage (V): choose 12 V, 24 V or 48 V.
  9. Read the result: Number of panels; the panel also shows Solar array needed (W), Battery bank, nominal (kWh) and Battery bank at that voltage (Ah).

How this calculator works

Energy balance: the array must replace each day's use on the sun of one day. Array watts = daily Wh ÷ (peak sun hours × derate). Panels = array watts ÷ panel rating, rounded up.

Peak sun hours equal the solar energy reaching the panels in kWh per square meter per day. For year-round off-grid use, take the lowest month for your site and tilt; the PVWatts calculator of the National Laboratory of the Rockies, a U.S. Department of Energy laboratory (pvwatts.nlr.gov), gives monthly solar radiation values for a chosen location.

Battery bank (kWh) = daily Wh × days of autonomy ÷ usable depth of discharge ÷ efficiency ÷ 1,000. Amp-hours = battery Wh ÷ bank voltage.

The derate covers wiring, temperature, soiling and charge-controller losses, and also the inverter and battery losses, because the array formula does not divide by the efficiency entered for the battery bank; enter the figure from your system designer. The result is a first sizing, not a wiring or code design.

The formula

  1. A=lpsh×d÷100
  2. Pa=ceil⁡(Ap)
Symbols used in the formula
SymbolMeaningUnit
lDaily energy useWh per day
pshPeak sun hours at your sitehours per day
dSystem derate, share of panel rating delivered%
pPanel ratingW
ASolar array neededW
PaNumber of panels
ceil(x)the smallest whole number not below x.

Worked example

Daily energy use (Wh per day)3,000
Peak sun hours at your site (hours per day)4.5
System derate, share of panel rating delivered75%
Panel rating (W)400
Days of autonomy2 days
Usable depth of discharge of the battery50%
Inverter and battery round-trip efficiency90%
Battery bank voltage (V)24 V
Solar array needed (W)889
Battery bank, nominal (kWh)13.33
Battery bank at that voltage (Ah)556
  1. A=3,0004.5×75÷100=888.889
  2. Pa=ceil⁡(888.889400)=3

Number of panels 3

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

What depth of discharge should I enter?

Use the usable share your battery maker allows for the cycle life you want. It is printed in the battery datasheet or warranty.

Why does a higher voltage give fewer amp-hours?

The stored energy is the same; amp-hours are energy divided by voltage, so a 48 V bank needs half the amp-hours of a 24 V bank.

Does this include a backup generator?

No. The array and batteries are sized to cover the load alone; a generator lets you choose fewer days of autonomy.

Questions answered