Skip to content
FiftyCalc Free calculators for all 50 states

Pipe Volume Calculator

Test cases replayed : 3 of 3 match · Methodology · No outside source listed

Enter the pipe size and length to get the water it holds in gallons, liters and cubic feet.

Result

Sample figures

Pipe volume (US gallons)—

Inside diameter used (inches) —

  • Volume per foot (US gallons)—
  • Pipe volume (liters)—
  • Pipe volume (cubic feet)—

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Pipe Volume Calculator

Diameter you know: choose Inside diameter or Outside diameter and wall thickness. Prefilled example: Inside diameter.

Diameter, in in: enter 0 or more. Prefilled example: 2.

Pipe length, in ft: enter 0 or more. Prefilled example: 100.

Number of pipes: enter 1 or more. Prefilled example: 1.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Diameter you know: choose Inside diameter or Outside diameter and wall thickness.
  2. Diameter, in in: enter 0 or more.
  3. Wall thickness (inches), with outside diameter: enter 0 or more.
  4. Pipe length, in ft: enter 0 or more.
  5. Number of pipes: enter 1 or more.
  6. Read the result: Pipe volume (US gallons); the panel also shows Inside diameter used (inches), Volume per foot (US gallons), Pipe volume (liters) and Pipe volume (cubic feet).

How this calculator works

Volume = π × (inside diameter ÷ 2)² × length. With inches and feet: gallons = π × (ID ÷ 2)² × length (ft) × 12 ÷ 231, since a US gallon is exactly 231 cubic inches.

If you know the outside diameter, the inside diameter is OD − 2 × wall thickness. Liters = gallons × 3.785411784.

The formula

  1. Id={dif m=1d−2×wotherwise
  2. Gpf=π×(Id÷2)2×12231
  3. Gal=Gpf×l×c
Symbols used in the formula
SymbolMeaningUnit
mDiameter you know (1: Inside diameter; 2: Outside diameter and wall thickness)
dDiameterin
wWall thickness (inches), with outside diameter
lPipe lengthft
cNumber of pipes
IdInside diameter usedinches
GpfVolume per footUS gallons
GalPipe volumeUS gallons

Worked example

Diameter you knowInside diameter
Diameter2 in
Pipe length100 ft
Number of pipes1
Inside diameter used (inches)2
Volume per foot (US gallons)0.1632
Pipe volume (liters)61.78
Pipe volume (cubic feet)2.1817
  1. Id=2
  2. Gpf=3.14159×(2÷2)2×12231=0.1632
  3. Gal=0.1632×100×1=16.32

Pipe volume (US gallons) 16.32

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

How much water is in 100 feet of 2-inch pipe?

With a 2-inch inside diameter, about 0.1632 gallons per foot, so 16.32 gallons for 100 feet.

Should I use the nominal pipe size?

Use the actual inside diameter. Nominal sizes are names; the inside diameter depends on the pipe schedule or SDR, so check the pipe's data sheet.

Questions answered

Related calculators