Skip to content
FiftyCalc Free calculators for all 50 states

Recessed Lighting Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

Enter the room size, the light level you want and the lumens of one recessed fixture (on its box).

Result

Sample figures

Recessed lights needed—

Lumens needed —

  • Spacing for an even grid (feet)—

The unit choice applies to the fields you fill in. Results stay in the units written with them.

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Recessed Lighting Calculator

Units: switches the fields between the two unit systems.

Room length, in ft: enter 0 or more. Prefilled example: 14.

Room width, in ft: enter 0 or more. Prefilled example: 12.

Target light level (foot-candles): enter 0 or more. Prefilled example: 20.

Lumens per fixture: enter 1 or more. Prefilled example: 650.

Affiliate link

This is an affiliate link. As an Amazon Associate I earn from qualifying purchases. This does not change the result.

Search Amazon for recessed lighting. Visit Amazon

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Units: switches the fields between the two unit systems.
  2. Room length, in ft: enter 0 or more.
  3. Room width, in ft: enter 0 or more.
  4. Target light level (foot-candles): enter 0 or more.
  5. Lumens per fixture: enter 1 or more.
  6. Read the result: Recessed lights needed; the panel also shows Lumens needed and Spacing for an even grid (feet).

How this calculator works

One foot-candle is one lumen per square foot, so lumens needed = floor area × foot-candles, and fixtures = lumens needed ÷ lumens per fixture, rounded up.

Spacing = √(area ÷ fixtures) gives the side of the square each light covers; place lights at half that distance from the walls. Dimmers let one layout cover several uses.

The formula

  1. N=L×W×fc
  2. N2=ceil⁡(Nlm)
Symbols used in the formula
SymbolMeaningUnit
LRoom lengthft
WRoom widthft
fcTarget light level (foot-candles)
lmLumens per fixture
NLumens needed
N2Recessed lights needed
ceil(x)the smallest whole number not below x.

Worked example

Room length14 ft
Room width12 ft
Target light level (foot-candles)20
Lumens per fixture650
Lumens needed3,360
Spacing for an even grid (feet)5.2915
  1. N=14×12×20=3,360
  2. N2=ceil⁡(3,360650)=6

Recessed lights needed 6

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

How many 650-lumen recessed lights for a 14 × 12 room at 20 foot-candles?

3,360 lumens ÷ 650 = 5.2, so 6 lights about 5.29 feet apart.

Do I count lumens or watts?

Lumens: they measure the light given, while watts measure power used.

Questions answered

Related calculators