Solar Inverter Size Calculator
Test cases replayed : 2 of 2 match · Methodology · No outside source listed
For a grid-tied system, enter the array size and the DC-to-AC ratio you design for. For an off-grid or backup inverter, enter the watts of the loads that run at the same time and the starting watts of the largest motor.
Result
Grid-tie inverter AC rating (kW AC)
Off-grid inverter continuous rating needed (W)
- Off-grid inverter surge rating needed (W)
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
Affiliate link
This is an affiliate link: FiftyCalc may earn a commission if you buy through it. This does not change the result.
ALLPOWERS sells portable power stations and portable solar panels. Visit ALLPOWERS
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Solar array size (kW DC, panel nameplate total): enter 0 or more.
- DC-to-AC ratio you design for: enter a number from 0.5 to 2.
- Off-grid: running watts of all loads on at the same time, in W: enter 0 or more.
- Off-grid: running watts of the largest motor load, in W: enter 0 or more.
- Off-grid: starting (surge) watts of that motor load, in W: enter 0 or more.
- Off-grid: margin you add to the continuous rating, in percent: enter a number from 0 to 100.
- Read the result: Grid-tie inverter AC rating (kW AC); the panel also shows Off-grid inverter continuous rating needed (W) and Off-grid inverter surge rating needed (W).
How this calculator works
Grid-tie: inverter AC rating = array DC rating ÷ DC-to-AC ratio. A ratio above 1 puts more panel watts on the inverter than it can output; in the hours when the array would produce more, the inverter limits (clips) the output. The ratio is a design choice and the default 1.2 is an example. Check the inverter datasheet for the highest DC power and input voltage it accepts.
Off-grid: continuous rating = running watts of everything that can be on at once × (1 + margin). Surge rating = running watts of the other loads + starting watts of the largest motor (pump, compressor), assuming the large motors do not start at the same moment. The margin is your choice; the default 25% is an example.
Running and starting watts are on the appliance nameplate or in its manual. A licensed installer sizes conductors and protection under the electrical code your state or city has adopted, which differs from place to place.
The formula
| Symbol | Meaning |
|---|---|
| Solar array size (kW DC, panel nameplate total) | |
| DC-to-AC ratio you design for | |
| Grid-tie inverter AC rating (kW AC) |
Worked example
| Solar array size (kW DC, panel nameplate total) | 7.2 |
|---|---|
| DC-to-AC ratio you design for | 1.2 |
| Off-grid: running watts of all loads on at the same time | 1,800 W |
| Off-grid: running watts of the largest motor load | 700 W |
| Off-grid: starting (surge) watts of that motor load | 2,400 W |
| Off-grid: margin you add to the continuous rating | 25% |
| Off-grid inverter continuous rating needed (W) | 2,250 |
|---|---|
| Off-grid inverter surge rating needed (W) | 3,500 |
Grid-tie inverter AC rating (kW AC) 6.00
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
Can the inverter be smaller than the solar array?
Yes. Grid-tie inverters are often rated below the array's DC nameplate because panels seldom deliver their full rating; the energy lost to clipping is small at moderate ratios.
Why does an off-grid inverter need a surge rating?
Motors draw a short burst of power when they start. If the inverter cannot supply it, the motor stalls or the inverter shuts down.
Does the battery voltage matter?
It decides which inverter models fit (12, 24 or 48 V); the wattage needs above stay the same.