Spring Rate Calculator
Test cases replayed : 2 of 2 match · Methodology · No outside source listed
Enter the wire size, the mean coil diameter, the number of active coils and the wire's shear modulus to get the spring rate.
Result
Spring rate (lbf/in)
Spring rate (N/m)
- Spring rate (N/mm)
- Spring index C = D ÷ d
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Shear modulus of the wire G: enter 0 or more.
- Modulus unit: choose psi or GPa.
- Wire diameter d: enter 0 or more.
- Mean coil diameter D: enter 0 or more.
- Length unit: choose inches (in) or millimeters (mm).
- Active coils Na: enter 0 or more.
- Read the result: Spring rate (lbf/in); the panel also shows Spring rate (N/m), Spring rate (N/mm) and Spring index C = D ÷ d.
How this calculator works
k = G × d⁴ ÷ (8 × D³ × Na), the standard rate of a helical spring (from torsion of the wire), with D the mean coil diameter and Na the active coils. G is the wire's shear modulus; take it from your wire maker.
1 psi = 6,894.757 Pa and 1 lbf/in = 175.1268 N/m (NIST SP 811, Appendix B.9 conversion factors, read on nist.gov on 2026-10-27).
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| Shear modulus of the wire G | ||
| Modulus unit | ||
| Wire diameter d | ||
| Mean coil diameter D | ||
| Length unit | ||
| Active coils Na | ||
| Spring rate (N/m) | ||
| Spring rate | lbf/in |
Worked example
| Shear modulus of the wire G | 11,500,000 |
|---|---|
| Modulus unit | psi |
| Wire diameter d | 0.08 |
| Mean coil diameter D | 0.75 |
| Length unit | inches (in) |
| Active coils Na | 10 |
| Spring rate (N/m) | 2,444.1997 |
|---|---|
| Spring rate (N/mm) | 2.4442 |
| Spring index C = D ÷ d | 9.375 |
Spring rate (lbf/in) 13.9567
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
What is the rate of 0.08 in wire, 0.75 in coils, 10 active coils, G = 11.5 Mpsi?
About 13.96 lbf/in.
Why do end coils not count?
Closed or ground end coils sit solid and do not deflect, so only the active coils set the rate.