Tankless Water Heater Size Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

A tankless heater must raise the incoming water to your set temperature at the full flow of the fixtures you run at once. Enter that flow and the two temperatures to get the heating power needed.

Result

Sample figures

Heat delivered to the water—BTU/h

Temperature rise (°F) —

  • Input rating needed at that efficiency (BTU per hour)—
  • Same heat for an electric unit (kW)—
  • Flow that heater can supply at this rise (gallons per minute)—

The unit choice applies to the fields you fill in. Results stay in the units written with them.

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Tankless Water Heater Size Calculator

Units: switches the fields between the two unit systems.

Peak hot water flow, all fixtures used at once (gallons per minute): enter a number from 0.1 to 20. Prefilled example: 4.

Incoming cold water temperature, in °F: enter a number from 32 to 90. Prefilled example: 50.

Desired hot water temperature, in °F: enter a number from 60 to 180. Prefilled example: 120.

Heater efficiency, heat delivered ÷ energy input, in percent: enter a number from 50 to 100. Prefilled example: 95.

Input rating of a heater you are considering, in BTU/h: enter 1,000 or more. Prefilled example: 199,000.

Affiliate link

This is an affiliate link. As an Amazon Associate I earn from qualifying purchases. This does not change the result.

Search Amazon for tankless water heaters. Visit Amazon

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Units: switches the fields between the two unit systems.
  2. Peak hot water flow, all fixtures used at once (gallons per minute): enter a number from 0.1 to 20.
  3. Incoming cold water temperature, in °F: enter a number from 32 to 90.
  4. Desired hot water temperature, in °F: enter a number from 60 to 180.
  5. Heater efficiency, heat delivered ÷ energy input, in percent: enter a number from 50 to 100.
  6. Input rating of a heater you are considering, in BTU/h: enter 1,000 or more.
  7. Read the result: Heat delivered to the water; the panel also shows Temperature rise (°F), Input rating needed at that efficiency (BTU per hour), Same heat for an electric unit (kW) and Flow that heater can supply at this rise (gallons per minute).

How this calculator works

Heat = flow × weight of water × temperature rise. One BTU raises one pound of water by 1 °F, and a U.S. gallon of water weighs about 8.33 lb, so BTU per hour = gallons per minute × 60 × 8.33 × temperature rise (°F).

Input needed = heat delivered ÷ efficiency. Electric power = BTU per hour ÷ 3,412.14 (1 kW = 3,412.14 BTU per hour). Flow a given heater can supply = input rating × efficiency ÷ (60 × 8.33 × temperature rise).

Peak flow is the sum of the flow rates of the fixtures that may run at the same time; the rated flow is printed on showerheads and faucets or in their specifications. Use the coldest incoming water temperature of the year at your home, because the rise, and so the size, is largest then.

This is a heat balance, not a product selection: the maker's flow-versus-rise chart, the gas line or electrical service, and venting rules decide which model fits.

The formula

  1. R=t−tin
  2. O={gpm×60×8.33×Rif R>0No result for these inputsotherwise
Symbols used in the formula
SymbolMeaningUnit
gpmPeak hot water flow, all fixtures used at oncegallons per minute
tinIncoming cold water temperature°F
tDesired hot water temperature°F
RResult of step 1
OHeat delivered to the waterBTU/h

Worked example

Peak hot water flow, all fixtures used at once (gallons per minute)4
Incoming cold water temperature50 °F
Desired hot water temperature120 °F
Heater efficiency, heat delivered ÷ energy input95%
Input rating of a heater you are considering199,000 BTU/h
Temperature rise (°F)70
Input rating needed at that efficiency (BTU per hour)147,309
Same heat for an electric unit (kW)41.0
Flow that heater can supply at this rise (gallons per minute)5.4
  1. R=120−50=70
  2. O=4×60×8.33×70=139,944

Heat delivered to the water 139,944 BTU/h

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

Why does the same heater deliver less hot water in winter?

Colder incoming water means a larger temperature rise, and the heater's fixed power spreads over that larger rise, so the flow it can heat drops.

Which efficiency should I enter?

Use the thermal efficiency or the efficiency figure published for the model. Electric resistance units deliver nearly all their input as heat, so an efficiency close to 100% is typical for them.

Is the electric kW figure what my panel must supply?

It is the heating power needed. The breaker and wire sizes for an electric tankless heater come from its installation manual and the electrical code.