Skip to content
FiftyCalc Free calculators for all 50 states

Biot Number Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

The Biot number compares heat flow resistance inside a body with that at its surface. Enter the heat transfer coefficient, the body's size and its conductivity.

Result

Sample figures

Biot number—

Characteristic length Lc = V ÷ A (m) —

  • Lumped capacitance model—

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Biot Number Calculator

Convection coefficient h (W/m²·K): enter 0 or more. Prefilled example: 25.

Body volume, in cm³: enter 0 or more. Prefilled example: 1,000.

Body surface area, in cm²: enter 0 or more. Prefilled example: 600.

Thermal conductivity k (W/m·K): enter 0 or more. Prefilled example: 45.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Convection coefficient h (W/m²·K): enter 0 or more.
  2. Body volume, in cm³: enter 0 or more.
  3. Body surface area, in cm²: enter 0 or more.
  4. Thermal conductivity k (W/m·K): enter 0 or more.
  5. Read the result: Biot number; the panel also shows Characteristic length Lc = V ÷ A (m) and Lumped capacitance model.

How this calculator works

Biot number Bi = h × Lc ÷ k, where h is the convection heat transfer coefficient, k the thermal conductivity of the solid and Lc = V ÷ A its characteristic length (volume divided by surface area).

Heat transfer textbooks (for example Incropera, Fundamentals of Heat and Mass Transfer) accept the lumped capacitance model, which treats the body as one uniform temperature, when Bi < 0.1.

The formula

  1. Lc=v÷a100
  2. Bi=h×Lck
Symbols used in the formula
SymbolMeaningUnit
hConvection coefficient hW/m²·K
vBody volumecm³
aBody surface areacm²
kThermal conductivity kW/m·K
LcCharacteristic length Lc = V ÷ Am
BiBiot number

Worked example

Convection coefficient h (W/m²·K)25
Body volume1,000 cm³
Body surface area600 cm²
Thermal conductivity k (W/m·K)45
Characteristic length Lc = V ÷ A (m)0.0167
Lumped capacitance modelValid (Bi < 0.1): the temperature inside stays nearly uniform
  1. Lc=1,000÷600100=0.0166667
  2. Bi=25×0.016666745=0.00925926

Biot number 0.0093

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

What is the Biot number of a 10 cm steel cube in air?

With h = 25 W/m²·K and k = 45 W/m·K, Lc = 1.667 cm and Bi ≈ 0.0093: lumped model valid.

What does a large Biot number mean?

Heat moves slowly inside compared with the surface, so the outside heats or cools first.