Carburetor CFM Calculator
Test cases replayed : 2 of 2 match · Methodology · No outside source listed
A four-stroke engine fills its cylinders once every two turns. Enter the displacement, the highest RPM you will use and the volumetric efficiency.
Result
Required airflowCFM
Airflow at 100% volumetric efficiency (CFM)
- Airflow (liters per second)
The unit choice applies to the fields you fill in. Results stay in the units written with them.
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Units: switches the fields between the two unit systems.
- Engine displacement, in cu in: enter 0 or more.
- Maximum engine speed, in RPM: enter 0 or more.
- Volumetric efficiency, in percent: enter a number from 10 to 130.
- Read the result: Required airflow; the panel also shows Airflow at 100% volumetric efficiency (CFM) and Airflow (liters per second).
How this calculator works
CFM = displacement (in³) × RPM × VE ÷ 3,456. The 3,456 is 1,728 cubic inches per cubic foot times 2, because a four-stroke engine takes in its full displacement once every two revolutions.
Volumetric efficiency is the share of the cylinders actually filled: a stock street engine fills less than a tuned race engine. 1 ft = 0.3048 m exactly (NIST SP 811, Appendix B (nist.gov/pml/special-publication-811, read 2026-10-27)).
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| Engine displacement | cu in | |
| Maximum engine speed | RPM | |
| Volumetric efficiency | % | |
| Required airflow | CFM |
Worked example
| Engine displacement | 350 cu in |
|---|---|
| Maximum engine speed | 6,000 RPM |
| Volumetric efficiency | 85% |
| Airflow at 100% volumetric efficiency (CFM) | 608 |
|---|---|
| Airflow (liters per second) | 243.7576 |
Required airflow 516 CFM
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
What CFM carburetor does a 350 need?
At 6,000 RPM and 85% volumetric efficiency, about 516 CFM; carburetors are usually picked at the next common size.
Does this work for a two-stroke engine?
No. A two-stroke fills once per revolution, so it uses 1,728 instead of 3,456.