Skip to content
FiftyCalc Free calculators for all 50 states

Darcy-Weisbach Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

Friction in a pipe turns pressure into heat along its length. Enter the Darcy friction factor (from the Moody chart or Colebrook equation), the pipe and the velocity.

Result

Sample figures

Head loss (meters of fluid)—

Head loss (feet of fluid) —

  • Pressure drop (kPa)—
  • Pressure drop (psi)—

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Darcy-Weisbach Calculator

Darcy friction factor f: enter 0 or more. Prefilled example: 0.02.

Pipe length, in m: enter 0 or more. Prefilled example: 100.

Inside diameter, in mm: enter 0.1 or more. Prefilled example: 100.

Mean flow velocity, in m/s: enter 0 or more. Prefilled example: 2.

Fluid density (kg/m³; enter your fluid's value): enter 0.01 or more. Prefilled example: 1,000.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Darcy friction factor f: enter 0 or more.
  2. Pipe length, in m: enter 0 or more.
  3. Inside diameter, in mm: enter 0.1 or more.
  4. Mean flow velocity, in m/s: enter 0 or more.
  5. Fluid density (kg/m³; enter your fluid's value): enter 0.01 or more.
  6. Read the result: Head loss (meters of fluid); the panel also shows Head loss (feet of fluid), Pressure drop (kPa) and Pressure drop (psi).

How this calculator works

Darcy-Weisbach: h_f = f × (L ÷ D) × v² ÷ (2g), and ΔP = ρ g h_f = f (L ÷ D) ρ v² ÷ 2, with f the Darcy friction factor, L the length, D the inside diameter, v the mean velocity and g = 9.80665 m/s² (CODATA 2022 values published by NIST (physics.nist.gov/cuu/Constants, read 2026-10-27)).

Use the Darcy (Moody) factor, which is four times the Fanning factor. 1 psi = 6,894.757 Pa and 1 ft = 0.3048 m (NIST SP 811, Appendix B (nist.gov/pml/special-publication-811, read 2026-10-27)).

The formula

  1. Hf=f×l÷(d÷1,000)×v22×9.80665
Symbols used in the formula
SymbolMeaningUnit
fDarcy friction factor f
lPipe lengthm
dInside diametermm
vMean flow velocitym/s
HfHead loss (meters of fluid)

Worked example

Darcy friction factor f0.02
Pipe length100 m
Inside diameter100 mm
Mean flow velocity2 m/s
Fluid density (kg/m³; enter your fluid's value)1,000
Head loss (feet of fluid)13.3821
Pressure drop (kPa)40
Pressure drop (psi)5.8015
  1. Hf=0.02×100÷(100÷1,000)×222×9.80665=4.07886

Head loss (meters of fluid) 4.0789

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

What head loss does 100 m of 100 mm pipe at 2 m/s give with f = 0.02?

About 4.0789 m of water, a pressure drop of about 40 kPa (5.8 psi).

How does velocity change the loss?

The loss grows with the square of velocity: double the flow, four times the friction loss (for the same f).