Darcy-Weisbach Calculator
Test cases replayed : 2 of 2 match · Methodology · No outside source listed
Friction in a pipe turns pressure into heat along its length. Enter the Darcy friction factor (from the Moody chart or Colebrook equation), the pipe and the velocity.
Result
Head loss (meters of fluid)
Head loss (feet of fluid)
- Pressure drop (kPa)
- Pressure drop (psi)
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Darcy friction factor f: enter 0 or more.
- Pipe length, in m: enter 0 or more.
- Inside diameter, in mm: enter 0.1 or more.
- Mean flow velocity, in m/s: enter 0 or more.
- Fluid density (kg/m³; enter your fluid's value): enter 0.01 or more.
- Read the result: Head loss (meters of fluid); the panel also shows Head loss (feet of fluid), Pressure drop (kPa) and Pressure drop (psi).
How this calculator works
Darcy-Weisbach: h_f = f × (L ÷ D) × v² ÷ (2g), and ΔP = ρ g h_f = f (L ÷ D) ρ v² ÷ 2, with f the Darcy friction factor, L the length, D the inside diameter, v the mean velocity and g = 9.80665 m/s² (CODATA 2022 values published by NIST (physics.nist.gov/cuu/Constants, read 2026-10-27)).
Use the Darcy (Moody) factor, which is four times the Fanning factor. 1 psi = 6,894.757 Pa and 1 ft = 0.3048 m (NIST SP 811, Appendix B (nist.gov/pml/special-publication-811, read 2026-10-27)).
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| Darcy friction factor f | ||
| Pipe length | m | |
| Inside diameter | mm | |
| Mean flow velocity | m/s | |
| Head loss (meters of fluid) |
Worked example
| Darcy friction factor f | 0.02 |
|---|---|
| Pipe length | 100 m |
| Inside diameter | 100 mm |
| Mean flow velocity | 2 m/s |
| Fluid density (kg/m³; enter your fluid's value) | 1,000 |
| Head loss (feet of fluid) | 13.3821 |
|---|---|
| Pressure drop (kPa) | 40 |
| Pressure drop (psi) | 5.8015 |
Head loss (meters of fluid) 4.0789
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
What head loss does 100 m of 100 mm pipe at 2 m/s give with f = 0.02?
About 4.0789 m of water, a pressure drop of about 40 kPa (5.8 psi).
How does velocity change the loss?
The loss grows with the square of velocity: double the flow, four times the friction loss (for the same f).