Darcy's Law Calculator
Test cases replayed : 2 of 2 match · Methodology · No outside source listed
Water seeps through porous ground at a rate set by the soil's hydraulic conductivity and the slope of the water table. Enter the conductivity, area, head difference and distance.
Result
Flow rate Q (m³/day)
Hydraulic gradient Δh ÷ L
- Darcy flux q = Q ÷ A (m/day)
- Average seepage velocity (m/day)
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Hydraulic conductivity K (m/day): enter 0 or more.
- Cross-sectional area of flow, in m²: enter 0 or more.
- Head difference Δh (m): enter 0 or more.
- Flow path length L, in m: enter 0.0001 or more.
- Effective porosity (fraction, e.g. 0.25): enter a number from 0.001 to 1.
- Read the result: Flow rate Q (m³/day); the panel also shows Hydraulic gradient Δh ÷ L, Darcy flux q = Q ÷ A (m/day) and Average seepage velocity (m/day).
How this calculator works
Darcy's law: Q = K A (Δh ÷ L), with K the hydraulic conductivity, A the cross-sectional area, Δh the drop in hydraulic head over the distance L. The Darcy flux is q = Q ÷ A; the water actually moves faster through the pores, at q ÷ n where n is the effective porosity.
It holds for slow, laminar flow, which covers most groundwater. Conductivity spans many orders of magnitude, from clays to gravels, so use a measured value.
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| Hydraulic conductivity K | m/day | |
| Cross-sectional area of flow | m² | |
| Head difference Δh | m | |
| Flow path length L | m | |
| Flow rate Q | m³/day |
Worked example
| Hydraulic conductivity K (m/day) | 10 |
|---|---|
| Cross-sectional area of flow | 100 m² |
| Head difference Δh (m) | 2 |
| Flow path length L | 50 m |
| Effective porosity (fraction, e.g. 0.25) | 0.25 |
| Darcy flux q = Q ÷ A (m/day) | 0.4 |
|---|---|
| Average seepage velocity (m/day) | 1.6 |
| Hydraulic gradient Δh ÷ L | 0.04 |
Flow rate Q (m³/day) 40
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
Is the Darcy flux the real water speed?
No. Water only flows through the pore space, so its average speed is the flux divided by the effective porosity.
What does a gradient of 0.04 mean?
The water table drops 4 cm for every meter of distance along the flow path.