Egress Window Calculator
Test cases replayed : 2 of 2 match · Methodology · Sources
Measure the clear opening the window gives when it is fully open from the inside, then check it against the four minimums of the International Residential Code (IRC) for emergency escape and rescue openings.
Result
Result
Net clear opening area (sq ft)
Reading the result
At a glance
What moves the result
Method and sources: How this calculator works, Sources
- Minimum area for this opening (sq ft)
- Area check
- Height check
- Width check
- Sill height check
- Clear height needed at this width (in)
The unit choice applies to the fields you fill in. Results stay in the units written with them.
Estimate for planning only, not tax, legal, financial or medical advice. Check important figures with the official source listed on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Units: switches the fields between the two unit systems.
- Net clear opening width, in in: enter 0 or more.
- Net clear opening height, in in: enter 0 or more.
- Sill height above the finished floor, in in: enter 0 or more.
- Where the opening is: choose Above grade (second floor and up) or Grade floor or below grade (basement).
- Read the result: Result; the panel also shows Net clear opening area (sq ft), Minimum area for this opening (sq ft), Area check, Height check, Width check, Sill height check and Clear height needed at this width (in).
Sources
- Emergency escape and rescue openings, 2020 Minnesota Residential Code Minnesota Department of Labor and Industry checked on 2026-11-02
How this calculator works
Net clear opening area (sq ft) = clear width (in) × clear height (in) ÷ 144. Measure the opening itself when the sash is opened normally from the inside, not the rough opening or the glass.
Model code minimums, 2018 International Residential Code sections R310.2.1 and R310.2.2: net clear opening of at least 5.7 sq ft (5 sq ft for grade floor or below-grade openings), net clear height of at least 24 in, net clear width of at least 20 in, and a sill no more than 44 in above the floor. Read in the Minnesota Department of Labor and Industry fact sheet "Emergency escapes and rescue openings, 2020 Minnesota Residential Code", which reproduces these sections as adopted in the 2020 Minnesota Residential Code, the 2018 IRC with Minnesota amendments (dli.mn.gov, read October 28, 2026).
Clear height needed = the larger of 24 in and minimum area × 144 ÷ width. Meeting only the minimum width and height (20 in × 24 in = 3.3 sq ft) never meets the area rule.
Each state and city adopts its own edition of the IRC, often with amendments, so the figures that apply to your home come from your local building department. A sill below grade also needs a window well (R310.2.3: at least 9 sq ft of horizontal area and 36 in of projection and width in the 2018 IRC).
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| Net clear opening width | in | |
| Net clear opening height | in | |
| Sill height above the finished floor | in | |
| One if Where the opening is is Grade floor or below grade (basement), zero otherwise | ||
| Result of step 1 | ||
| Result of step 2 | ||
| Result | ||
round(x, d) | x rounded to d decimal places, or to a whole number without d. |
Worked example
| Net clear opening width | 24 in |
|---|---|
| Net clear opening height | 36 in |
| Sill height above the finished floor | 40 in |
| Where the opening is | Above grade (second floor and up) |
| Net clear opening area (sq ft) | 6.00 |
|---|---|
| Minimum area for this opening (sq ft) | 5.7 |
| Area check | Meets |
| Height check | Meets (24 in or more) |
| Width check | Meets (20 in or more) |
| Sill height check | Meets (44 in or less) |
| Clear height needed at this width (in) | 34.2 |
Result Meets all four IRC R310.2 minimums (area, height, width, sill)
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
Is a 24 by 36 inch opening big enough?
Yes, if those are clear opening dimensions: 24 × 36 ÷ 144 = 6.0 sq ft, above the 5.7 sq ft minimum, with height and width above 24 in and 20 in. The sill must also be no more than 44 in above the floor.
Why is the basement minimum only 5 sq ft?
The IRC sets 5 sq ft for grade-floor and below-grade openings, as an exception to the 5.7 sq ft required for other openings (R310.2.1). The Minnesota fact sheet explains that the minimum openings are set so that emergency responders wearing protective equipment can enter the dwelling.
Does my city use these numbers?
Many U.S. jurisdictions adopt the IRC, but the edition and local amendments vary. Ask your building department which code applies before you buy a window.