Find the log mean temperature difference that drives heat transfer in a heat exchanger.
Result
LMTD°
ΔT₁ (degrees)
- ΔT₂ (degrees)
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Flow arrangement: choose Counterflow or Parallel flow.
- Hot fluid inlet (°F or °C): enter a number.
- Hot fluid outlet: enter a number.
- Cold fluid inlet: enter a number.
- Cold fluid outlet: enter a number.
- Read the result: LMTD; the panel also shows ΔT₁ (degrees) and ΔT₂ (degrees).
How this calculator works
LMTD = (ΔT₁ − ΔT₂) ÷ ln(ΔT₁ ÷ ΔT₂). In counterflow ΔT₁ = T_hot,in − T_cold,out and ΔT₂ = T_hot,out − T_cold,in; in parallel flow ΔT₁ = T_hot,in − T_cold,in and ΔT₂ = T_hot,out − T_cold,out. When the two differences are equal, LMTD equals that difference.
The heat duty is then Q = U × A × LMTD (times a correction factor F for multipass and crossflow exchangers). Use one temperature scale throughout; the result is a temperature difference in the same degrees.
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| Flow arrangement (1: Counterflow; 2: Parallel flow) | ||
| Hot fluid inlet | °F or °C | |
| Hot fluid outlet | ||
| Cold fluid inlet | ||
| Cold fluid outlet | ||
| ΔT₁ | degrees | |
| ΔT₂ | degrees | |
| LMTD | ° |
Worked example
| Flow arrangement | Counterflow |
|---|---|
| Hot fluid inlet (°F or °C) | 200 |
| Hot fluid outlet | 140 |
| Cold fluid inlet | 60 |
| Cold fluid outlet | 110 |
| ΔT₁ (degrees) | 90 |
|---|---|
| ΔT₂ (degrees) | 80 |
LMTD 84.9019 °
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
Why not use the plain average temperature difference?
The difference changes along the exchanger in an exponential way; the log mean is the exact average for constant U and specific heats.
Why is counterflow better?
For the same temperatures it gives a larger LMTD, so it needs less area, and the cold outlet can get hotter than the hot outlet.