Manometer Calculator
Test cases replayed : 2 of 2 match · Methodology · No outside source listed
Turn the height difference in a U-tube manometer into a pressure difference.
Result
Pressure differencePa
Pressure difference (kPa)
- Pressure difference (inH₂O at 39.2 °F)
- Pressure difference (psi)
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Height difference of the columns: enter 0 or more.
- Height unit: choose Millimeters (mm), Inches (in) or Centimeters (cm).
- Density of the manometer fluid (kg/m³): enter 0 or more.
- Density of the fluid being measured (kg/m³): enter 0 or more.
- Read the result: Pressure difference; the panel also shows Pressure difference (kPa), Pressure difference (inH₂O at 39.2 °F) and Pressure difference (psi).
How this calculator works
Hydrostatic balance in a U-tube: Δp = (ρ_m − ρ_f) × g × h, where ρ_m is the manometer liquid's density, ρ_f the density of the fluid above it on both sides and h the height difference. When measuring a gas, ρ_f is small and Δp ≈ ρ_m × g × h.
g = 9.80665 m/s² (CODATA 2022 values from NIST (physics.nist.gov/cuu/Constants/Table/allascii.txt, read October 27, 2026)); 1 inH₂O (39.2 °F) = 249.082 Pa and 1 psi = 6,894.757 Pa (NIST SP 811, Appendix B.9 (nist.gov/pml/special-publication-811, read October 27, 2026)). The default densities are examples (water in the tube, air above); enter yours.
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| Height difference of the columns | ||
| Height unit | ||
| Density of the manometer fluid | kg/m³ | |
| Density of the fluid being measured | kg/m³ | |
| Pressure difference | Pa |
Worked example
| Height difference of the columns | 100 |
|---|---|
| Height unit | Millimeters (mm) |
| Density of the manometer fluid (kg/m³) | 1,000 |
| Density of the fluid being measured (kg/m³) | 1.2 |
| Pressure difference (kPa) | 0.9795 |
|---|---|
| Pressure difference (inH₂O at 39.2 °F) | 3.9324 |
| Pressure difference (psi) | 0.1421 |
Pressure difference 979.4882 Pa
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
Why use mercury instead of water?
A denser liquid gives a shorter column for the same pressure, so it suits higher pressures; water or oil gives a finer reading at low pressures.
Does the tube diameter matter?
No, only the height difference and the densities do (for tubes wide enough that capillary effects are small).