Skip to content
FiftyCalc Free calculators for all 50 states

Manometer Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

Turn the height difference in a U-tube manometer into a pressure difference.

Result

Sample figures

Pressure difference—Pa

Pressure difference (kPa) —

  • Pressure difference (inH₂O at 39.2 °F)—
  • Pressure difference (psi)—

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Manometer Calculator

Height difference of the columns: enter 0 or more. Prefilled example: 100.

Height unit

Height unit: choose Millimeters (mm), Inches (in) or Centimeters (cm). Prefilled example: Millimeters (mm).

Density of the manometer fluid (kg/m³): enter 0 or more. Prefilled example: 1,000.

Density of the fluid being measured (kg/m³): enter 0 or more. Prefilled example: 1.2.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Height difference of the columns: enter 0 or more.
  2. Height unit: choose Millimeters (mm), Inches (in) or Centimeters (cm).
  3. Density of the manometer fluid (kg/m³): enter 0 or more.
  4. Density of the fluid being measured (kg/m³): enter 0 or more.
  5. Read the result: Pressure difference; the panel also shows Pressure difference (kPa), Pressure difference (inH₂O at 39.2 °F) and Pressure difference (psi).

How this calculator works

Hydrostatic balance in a U-tube: Δp = (ρ_m − ρ_f) × g × h, where ρ_m is the manometer liquid's density, ρ_f the density of the fluid above it on both sides and h the height difference. When measuring a gas, ρ_f is small and Δp ≈ ρ_m × g × h.

g = 9.80665 m/s² (CODATA 2022 values from NIST (physics.nist.gov/cuu/Constants/Table/allascii.txt, read October 27, 2026)); 1 inH₂O (39.2 °F) = 249.082 Pa and 1 psi = 6,894.757 Pa (NIST SP 811, Appendix B.9 (nist.gov/pml/special-publication-811, read October 27, 2026)). The default densities are examples (water in the tube, air above); enter yours.

The formula

  1. Dp=(rm−rf)×9.80665×h×hu
Symbols used in the formula
SymbolMeaningUnit
hHeight difference of the columns
huHeight unit
rmDensity of the manometer fluidkg/m³
rfDensity of the fluid being measuredkg/m³
DpPressure differencePa

Worked example

Height difference of the columns100
Height unitMillimeters (mm)
Density of the manometer fluid (kg/m³)1,000
Density of the fluid being measured (kg/m³)1.2
Pressure difference (kPa)0.9795
Pressure difference (inH₂O at 39.2 °F)3.9324
Pressure difference (psi)0.1421
  1. Dp=(1,000−1.2)×9.80665×100×0.001=979.488

Pressure difference 979.4882 Pa

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.