SCFM Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

Enter the actual airflow with its gauge pressure and temperature, and the standard conditions you use, to get SCFM.

Result

Sample figures

Standard flow (SCFM)—

Standard flow (m³/min) —

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

SCFM Calculator

Actual flow (ACFM, ft³/min): enter 0 or more. Prefilled example: 100.

Gauge pressure at the flow point (psig): enter 0 or more. Prefilled example: 100.

Local atmospheric pressure (psia): enter 0 or more. Prefilled example: 14.696.

Gas temperature at the flow point, in °F: enter a number. Prefilled example: 80.

Standard pressure (psia): enter 0 or more. Prefilled example: 14.696.

Standard temperature, in °F: enter a number. Prefilled example: 68.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Actual flow (ACFM, ft³/min): enter 0 or more.
  2. Gauge pressure at the flow point (psig): enter 0 or more.
  3. Local atmospheric pressure (psia): enter 0 or more.
  4. Gas temperature at the flow point, in °F: enter a number.
  5. Standard pressure (psia): enter 0 or more.
  6. Standard temperature, in °F: enter a number.
  7. Read the result: Standard flow (SCFM); the panel also shows Standard flow (m³/min).

How this calculator works

SCFM = ACFM × (P_actual ÷ P_std) × (T_std ÷ T_actual), from the ideal gas law, with absolute pressures (psia = psig + atmospheric) and absolute temperatures (°R = °F + 459.67).

Standard conditions differ between industries and standards; enter the ones your supplier or standard uses. The default 14.696 psia is one standard atmosphere (101,325 Pa ÷ 6,894.757 Pa/psi, NIST SP 811, Appendix B.9 conversion factors, read on nist.gov on 2026-10-27); 68 °F is an example default. 1 ft³ = 0.02831685 m³.

The formula

  1. S=a×(pg+p)÷ps×(ts+459.67)t+459.67
Symbols used in the formula
SymbolMeaningUnit
aActual flow (ACFM, ft³/min)
pgGauge pressure at the flow point (psig)
pLocal atmospheric pressure (psia)
tGas temperature at the flow point°F
psStandard pressure (psia)
tsStandard temperature°F
SStandard flow (SCFM)

Worked example

Actual flow (ACFM, ft³/min)100
Gauge pressure at the flow point (psig)100
Local atmospheric pressure (psia)14.696
Gas temperature at the flow point80 °F
Standard pressure (psia)14.696
Standard temperature68 °F
Standard flow (m³/min)21.6087
  1. S=100×(100+14.696)÷14.696×(68+459.67)80+459.67=763.103

Standard flow (SCFM) 763.1032

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

Is SCFM larger than ACFM?

For compressed air above atmospheric pressure, yes: the same actual volume holds more gas than at standard pressure.

What is 100 ACFM at 100 psig and 80 °F in SCFM?

About 763.10 SCFM with 14.696 psia atmospheric pressure and 14.696 psia, 68 °F standard conditions.