Skip to content
FiftyCalc Free calculators for all 50 states

Thermal Resistance Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

Enter the layer thickness, its thermal conductivity and area, and the temperature difference to get its thermal resistance and heat flow.

Result

Sample figures

Thermal resistance R = L ÷ (kA) (K/W)—

Area resistance RSI = L ÷ k (m²·K/W) —

  • US R-value (ft²·°F·h/Btu)—
  • Heat flow ΔT ÷ R (W)—

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Thermal Resistance Calculator

Thickness, in mm: enter 0 or more. Prefilled example: 100.

Thermal conductivity k (W/(m·K)): enter 0 or more. Prefilled example: 0.04.

Area, in m²: enter 0 or more. Prefilled example: 10.

Temperature difference (K or °C): enter a number. Prefilled example: 20.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Thickness, in mm: enter 0 or more.
  2. Thermal conductivity k (W/(m·K)): enter 0 or more.
  3. Area, in m²: enter 0 or more.
  4. Temperature difference (K or °C): enter a number.
  5. Read the result: Thermal resistance R = L ÷ (kA) (K/W); the panel also shows Area resistance RSI = L ÷ k (m²·K/W), US R-value (ft²·°F·h/Btu) and Heat flow ΔT ÷ R (W).

How this calculator works

R = L ÷ (k × A) for conduction through a flat layer (Fourier's law), and the heat flow is Q = ΔT ÷ R. The area-normalized value L ÷ k is the RSI used for insulation.

US R-value: 1 ft²·°F·h/Btu = 0.1761102 m²·K/W (NIST SP 811, Appendix B.9 conversion factors, read on nist.gov on 2026-10-27).

The formula

  1. Rsi=l÷1,000k
  2. R=Rsia
Symbols used in the formula
SymbolMeaningUnit
lThicknessmm
kThermal conductivity k (W/(m·K))
aAream²
RsiArea resistance RSI = L ÷ km²·K/W
RThermal resistance R = L ÷ (kA)K/W

Worked example

Thickness100 mm
Thermal conductivity k (W/(m·K))0.04
Area10 m²
Temperature difference (K or °C)20
Area resistance RSI = L ÷ k (m²·K/W)2.5
US R-value (ft²·°F·h/Btu)14.1957
Heat flow ΔT ÷ R (W)80
  1. Rsi=100÷1,0000.04=2.5
  2. R=2.510=0.25

Thermal resistance R = L ÷ (kA) (K/W) 0.25

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

What is the RSI of 100 mm of insulation with k = 0.04?

2.5 m²·K/W, about R-14.2 in US units.

How do layers combine?

Resistances in series add: sum the L ÷ k of each layer.

Related calculators