Coaxial Cable Impedance Calculator
Test cases replayed : 2 of 2 match · Methodology · Sources
Enter the inside diameter of the shield, the diameter of the center conductor and the dielectric constant of the insulation between them.
Result
Characteristic impedance, Z0Ω
Velocity factor
Reading the result
At a glance
What moves the result
Method and sources: How this calculator works, Sources
- Capacitance (pF per meter)
- Inductance (nH per meter)
Estimate for planning only, not tax, legal, financial or medical advice. Check important figures with the official source listed on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Shield inside diameter, D (any unit): enter 0 or more.
- Center conductor diameter, d (same unit): enter 0 or more.
- Dielectric constant of the insulation, εr (1 = air): enter 1 or more.
- Read the result: Characteristic impedance, Z0; the panel also shows Velocity factor, Capacitance (pF per meter) and Inductance (nH per meter).
Sources
- Fundamental Physical Constants, 2022 CODATA adjustment National Institute of Standards and Technology (NIST) checked on 2026-11-01
How this calculator works
Characteristic impedance of a coaxial line: Z0 = (1 / 2π) × √(μ0 / (ε0 εr)) × ln(D / d) = μ0 c / (2π √εr) × ln(D / d), where D is the inside diameter of the outer conductor, d the diameter of the inner conductor and εr the relative permittivity of the insulation. Only the ratio D/d matters, so any unit works.
Constants from NIST CODATA (physics.nist.gov/cuu, read 2026-10-27): speed of light c = 299,792,458 m/s (exact) and vacuum magnetic permeability μ0 = 1.25663706127 × 10⁻⁶ N/A²; ε0 = 1 / (μ0 c²).
Per meter of cable: capacitance C = 2π ε0 εr / ln(D/d), inductance L = (μ0 / 2π) × ln(D/d). Velocity factor = 1/√εr, the speed of a signal in the cable as a share of the speed of light.
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| Shield inside diameter, D | any unit | |
| Center conductor diameter, d | same unit | |
| Dielectric constant of the insulation, εr (1 = air) | ||
| Characteristic impedance, Z0 | Ω |
Worked example
| Shield inside diameter, D (any unit) | 4.7 |
|---|---|
| Center conductor diameter, d (same unit) | 1.4 |
| Dielectric constant of the insulation, εr (1 = air) | 2.25 |
| Velocity factor | 66.67% |
|---|---|
| Capacitance (pF per meter) | 103.3557 |
| Inductance (nH per meter) | 242.2181 |
Characteristic impedance, Z0 48.4101 Ω
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
Why do coax cables come in 50 and 75 ohm versions?
The impedance is set by the D/d ratio and the insulation. Different ratios suit different uses; what matters is that the cable, connectors and equipment all share the same impedance to avoid reflections.
Does cable length change its impedance?
No. Characteristic impedance depends only on the cross-section (D, d and εr), not on length. Length changes loss and delay.
What is the impedance of an air-insulated line with D/d = 3?
With εr = 1, Z0 = 59.96 × ln 3, about 65.87 ohms.