Skip to content
FiftyCalc Free calculators for all 50 states

Coaxial Cable Impedance Calculator

Test cases replayed : 2 of 2 match · Methodology · Sources

Enter the inside diameter of the shield, the diameter of the center conductor and the dielectric constant of the insulation between them.

Result

Sample figures

Characteristic impedance, Z0—Ω

Velocity factor —

  • Capacitance (pF per meter)—
  • Inductance (nH per meter)—

Estimate for planning only, not tax, legal, financial or medical advice. Check important figures with the official source listed on this page.

Coaxial Cable Impedance Calculator

Shield inside diameter, D (any unit): enter 0 or more. Prefilled example: 4.7.

Center conductor diameter, d (same unit): enter 0 or more. Prefilled example: 1.4.

Dielectric constant of the insulation, εr (1 = air): enter 1 or more. Prefilled example: 2.25.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Shield inside diameter, D (any unit): enter 0 or more.
  2. Center conductor diameter, d (same unit): enter 0 or more.
  3. Dielectric constant of the insulation, εr (1 = air): enter 1 or more.
  4. Read the result: Characteristic impedance, Z0; the panel also shows Velocity factor, Capacitance (pF per meter) and Inductance (nH per meter).

Sources

How this calculator works

Characteristic impedance of a coaxial line: Z0 = (1 / 2π) × √(μ0 / (ε0 εr)) × ln(D / d) = μ0 c / (2π √εr) × ln(D / d), where D is the inside diameter of the outer conductor, d the diameter of the inner conductor and εr the relative permittivity of the insulation. Only the ratio D/d matters, so any unit works.

Constants from NIST CODATA (physics.nist.gov/cuu, read 2026-10-27): speed of light c = 299,792,458 m/s (exact) and vacuum magnetic permeability μ0 = 1.25663706127 × 10⁻⁶ N/A²; ε0 = 1 / (μ0 c²).

Per meter of cable: capacitance C = 2π ε0 εr / ln(D/d), inductance L = (μ0 / 2π) × ln(D/d). Velocity factor = 1/√εr, the speed of a signal in the cable as a share of the speed of light.

The formula

  1. Z=299,792,458×0.000001256637061272×π×er×ln⁡(Dd2)
Symbols used in the formula
SymbolMeaningUnit
DShield inside diameter, Dany unit
d2Center conductor diameter, dsame unit
erDielectric constant of the insulation, εr (1 = air)
ZCharacteristic impedance, Z0Ω

Worked example

Shield inside diameter, D (any unit)4.7
Center conductor diameter, d (same unit)1.4
Dielectric constant of the insulation, εr (1 = air)2.25
Velocity factor66.67%
Capacitance (pF per meter)103.3557
Inductance (nH per meter)242.2181
  1. Z=299,792,458×0.000001256637061272×3.14159×2.25×ln⁡(4.71.4)=48.4101

Characteristic impedance, Z0 48.4101 Ω

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

Why do coax cables come in 50 and 75 ohm versions?

The impedance is set by the D/d ratio and the insulation. Different ratios suit different uses; what matters is that the cable, connectors and equipment all share the same impedance to avoid reflections.

Does cable length change its impedance?

No. Characteristic impedance depends only on the cross-section (D, d and εr), not on length. Length changes loss and delay.

What is the impedance of an air-insulated line with D/d = 3?

With εr = 1, Z0 = 59.96 × ln 3, about 65.87 ohms.