Skip to content
FiftyCalc Free calculators for all 50 states

Capacitive Transformerless Power Supply Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

A capacitive dropper uses a capacitor's reactance instead of a transformer to limit current from the mains. Such a circuit is not isolated from the line; it is for designers who know the safety rules.

Result

Sample figures

Approximate available current—mA

Capacitor reactance (ohms) —

  • Capacitor for the target current (µF)—

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Capacitive Transformerless Power Supply Calculator

Mains voltage (V rms): enter 0 or more. Prefilled example: 120.

Mains frequency, in Hz: enter 1 or more. Prefilled example: 60.

Dropper capacitor, in µF: enter 0 or more. Prefilled example: 0.47.

DC output voltage, in V: enter 0 or more. Prefilled example: 12.

Target output current, in mA: enter 0 or more. Prefilled example: 30.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Mains voltage (V rms): enter 0 or more.
  2. Mains frequency, in Hz: enter 1 or more.
  3. Dropper capacitor, in µF: enter 0 or more.
  4. DC output voltage, in V: enter 0 or more.
  5. Target output current, in mA: enter 0 or more.
  6. Read the result: Approximate available current; the panel also shows Capacitor reactance (ohms) and Capacitor for the target current (µF).

How this calculator works

The capacitor's reactance Xc = 1 ÷ (2π f C) limits the current: I ≈ (Vmains − Vout) ÷ Xc, a first estimate that treats the output voltage as subtracted from the mains rms value. Turned around, C ≈ I ÷ (2π f (Vmains − Vout)).

The output has no isolation from the line, so touching any part of the circuit can be lethal. Real designs add a series resistor, a bleeder resistor across the capacitor, a zener or regulator and a safety-rated (X2) capacitor.

The formula

  1. Xc=12×π×f×cuf÷1,000,000
  2. Ima=v−voXc×1,000
Symbols used in the formula
SymbolMeaningUnit
vMains voltage (V rms)
fMains frequencyHz
cufDropper capacitorµF
voDC output voltageV
XcCapacitor reactanceohms
ImaApproximate available currentmA

Worked example

Mains voltage (V rms)120
Mains frequency60 Hz
Dropper capacitor0.47 µF
DC output voltage12 V
Target output current30 mA
Capacitor reactance (ohms)5,643.7923
Capacitor for the target current (µF)0.7368
  1. Xc=12×3.14159×60×0.47÷1,000,000=5,643.79
  2. Ima=120−125,643.79×1,000=19.1361

Approximate available current 19.1361 mA

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

Why use a capacitor instead of a resistor?

An ideal capacitor drops voltage without turning power into heat, because its current is out of phase with the voltage.

Does the current change with load?

Roughly no: the dropper acts like a current source set by the capacitor, which is why the output needs a zener to clamp the voltage.

Related calculators