Capacitive Transformerless Power Supply Calculator
Test cases replayed : 2 of 2 match · Methodology · No outside source listed
A capacitive dropper uses a capacitor's reactance instead of a transformer to limit current from the mains. Such a circuit is not isolated from the line; it is for designers who know the safety rules.
Result
Approximate available currentmA
Capacitor reactance (ohms)
- Capacitor for the target current (µF)
Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.
This browser did not allow copying. The sentence is in the box below, already selected: copy it with your keyboard or the menu.
How to use this calculator
Fill in the fields in this order; each step takes you to its field.
- Mains voltage (V rms): enter 0 or more.
- Mains frequency, in Hz: enter 1 or more.
- Dropper capacitor, in µF: enter 0 or more.
- DC output voltage, in V: enter 0 or more.
- Target output current, in mA: enter 0 or more.
- Read the result: Approximate available current; the panel also shows Capacitor reactance (ohms) and Capacitor for the target current (µF).
How this calculator works
The capacitor's reactance Xc = 1 ÷ (2π f C) limits the current: I ≈ (Vmains − Vout) ÷ Xc, a first estimate that treats the output voltage as subtracted from the mains rms value. Turned around, C ≈ I ÷ (2π f (Vmains − Vout)).
The output has no isolation from the line, so touching any part of the circuit can be lethal. Real designs add a series resistor, a bleeder resistor across the capacitor, a zener or regulator and a safety-rated (X2) capacitor.
The formula
| Symbol | Meaning | Unit |
|---|---|---|
| Mains voltage (V rms) | ||
| Mains frequency | Hz | |
| Dropper capacitor | µF | |
| DC output voltage | V | |
| Capacitor reactance | ohms | |
| Approximate available current | mA |
Worked example
| Mains voltage (V rms) | 120 |
|---|---|
| Mains frequency | 60 Hz |
| Dropper capacitor | 0.47 µF |
| DC output voltage | 12 V |
| Target output current | 30 mA |
| Capacitor reactance (ohms) | 5,643.7923 |
|---|---|
| Capacitor for the target current (µF) | 0.7368 |
Approximate available current 19.1361 mA
Each step uses the unrounded value of the step before it; figures on this page are rounded for display.
Frequently asked questions
Why use a capacitor instead of a resistor?
An ideal capacitor drops voltage without turning power into heat, because its current is out of phase with the voltage.
Does the current change with load?
Roughly no: the dropper acts like a current source set by the capacitor, which is why the output needs a zener to clamp the voltage.