Skip to content
FiftyCalc Free calculators for all 50 states

Flyback Converter Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

Enter the input voltage, the duty cycle and the transformer turns ratio (secondary ÷ primary).

Result

Sample figures

Output voltage—V

Duty cycle for the target output (%) —

  • Switch voltage when off, without spikes (V)—

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Flyback Converter Calculator

Input voltage, in V: enter 0 or more. Prefilled example: 48.

Duty cycle, in percent: enter a number from 0 to 99. Prefilled example: 40.

Turns ratio Ns ÷ Np: enter 0 or more. Prefilled example: 0.25.

Target output voltage, in V: enter 0 or more. Prefilled example: 12.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Input voltage, in V: enter 0 or more.
  2. Duty cycle, in percent: enter a number from 0 to 99.
  3. Turns ratio Ns ÷ Np: enter 0 or more.
  4. Target output voltage, in V: enter 0 or more.
  5. Read the result: Output voltage; the panel also shows Duty cycle for the target output (%) and Switch voltage when off, without spikes (V).

How this calculator works

Ideal flyback in continuous conduction: V_out = V_in × (Ns ÷ Np) × D ÷ (1 − D), so D = V_out ÷ (V_out + V_in × Ns/Np). While the switch is off it sees V_in plus the reflected output V_out × Np/Ns.

The formulas ignore diode and switch drops, winding resistance and leakage-inductance spikes, which add to the real switch voltage; discontinuous mode follows a different relation.

The formula

  1. Vo=vin×nr×(D÷100)1−D÷100
Symbols used in the formula
SymbolMeaningUnit
vinInput voltageV
DDuty cycle%
nrTurns ratio Ns ÷ Np
VoOutput voltageV

Worked example

Input voltage48 V
Duty cycle40%
Turns ratio Ns ÷ Np0.25
Target output voltage12 V
Duty cycle for the target output (%)50%
Switch voltage when off, without spikes (V)80.00
  1. Vo=48×0.25×(40÷100)1−40÷100=8

Output voltage 8.00 V

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

What does a 48 V flyback with D = 40% and Ns/Np = 0.25 give?

About 8.00 V; for 12 V the duty cycle must be 50%.

Why can the duty cycle not reach 100%?

The transformer stores energy while the switch is on and delivers it while it is off; with no off-time no energy reaches the output.

Related calculators