Forward Converter Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

Enter the input voltage, the duty cycle and the transformer turns ratio (secondary ÷ primary).

Result

Sample figures

Output voltage—V

Duty cycle for the target output (%) —

  • Switch voltage with a 1:1 reset winding (V)—

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Forward Converter Calculator

Input voltage, in V: enter 0 or more. Prefilled example: 48.

Duty cycle, in percent: enter a number from 0 to 99. Prefilled example: 40.

Turns ratio Ns ÷ Np: enter 0 or more. Prefilled example: 0.5.

Target output voltage, in V: enter 0 or more. Prefilled example: 12.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Input voltage, in V: enter 0 or more.
  2. Duty cycle, in percent: enter a number from 0 to 99.
  3. Turns ratio Ns ÷ Np: enter 0 or more.
  4. Target output voltage, in V: enter 0 or more.
  5. Read the result: Output voltage; the panel also shows Duty cycle for the target output (%) and Switch voltage with a 1:1 reset winding (V).

How this calculator works

Ideal forward converter in continuous conduction: V_out = V_in × (Ns ÷ Np) × D. It works like a buck converter behind a transformer.

With a reset winding of as many turns as the primary, the core resets only if D stays at or below 50%, and the switch sees twice the input voltage. Diode drops and losses are ignored.

The formula

  1. Vo=vin×nr×D100
Symbols used in the formula
SymbolMeaningUnit
vinInput voltageV
DDuty cycle%
nrTurns ratio Ns ÷ Np
VoOutput voltageV

Worked example

Input voltage48 V
Duty cycle40%
Turns ratio Ns ÷ Np0.5
Target output voltage12 V
Duty cycle for the target output (%)50%
Switch voltage with a 1:1 reset winding (V)96.00
  1. Vo=48×0.5×40100=9.6

Output voltage 9.60 V

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

What does a 48 V forward converter at 40% duty and Ns/Np = 0.5 give?

9.60 V; a 12 V output needs a duty cycle of 50%.

How is it different from a flyback?

A forward converter passes energy while the switch is on and uses an output inductor; a flyback stores energy in the transformer and releases it when the switch turns off.

Related calculators