Skip to content
FiftyCalc Free calculators for all 50 states

Fuel Pump Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

Enter the horsepower you plan to make, the engine's BSFC and a margin for pressure and voltage drop at the pump.

Result

Sample figures

Pump flow needed (US gal/hr)—

Pump flow needed (L/hr) —

  • Fuel flow needed (lb/hr)—

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Fuel Pump Calculator

Target power (at the crank), in hp: enter 0 or more. Prefilled example: 500.

BSFC (lb/hp·h, from your engine builder; example): enter 0 or more. Prefilled example: 0.5.

Safety margin, in percent: enter 0 or more. Prefilled example: 20.

Fuel density (lb/gal, example for gasoline): enter 0 or more. Prefilled example: 6.0.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Target power (at the crank), in hp: enter 0 or more.
  2. BSFC (lb/hp·h, from your engine builder; example): enter 0 or more.
  3. Safety margin, in percent: enter 0 or more.
  4. Fuel density (lb/gal, example for gasoline): enter 0 or more.
  5. Read the result: Pump flow needed (US gal/hr); the panel also shows Fuel flow needed (lb/hr) and Pump flow needed (L/hr).

How this calculator works

Fuel flow = horsepower × BSFC × (1 + margin). Gallons per hour = lb/hr ÷ fuel density; liters per hour = gallons × 3.785412 (NIST Special Publication 811, Appendix B.9 (https://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9, read 2026-10-27)).

Pumps are rated at a given pressure and voltage, and deliver less at higher pressure (boost-referenced regulators raise it under boost). Check the flow on the pump maker's chart at your real pressure. The density default is an example within the range of the U.S. Department of Energy (EERE) table "Properties of Fuels", gasoline density 6.0–6.5 lb/gal at 60 °F, as reproduced at https://www.BuildItSolar.com/References/EEREfueltable.pdf (read 2026-10-27).

The formula

  1. Lb=hp×b×(1+m100)
  2. Gph=Lbdn
Symbols used in the formula
SymbolMeaningUnit
hpTarget power (at the crank)hp
bBSFC (lb/hp·h, from your engine builder; example)
mSafety margin%
dnFuel density (lb/gal, example for gasoline)
LbFuel flow needed (lb/hr)
GphPump flow needed (US gal/hr)

Worked example

Target power (at the crank)500 hp
BSFC (lb/hp·h, from your engine builder; example)0.5
Safety margin20%
Fuel density (lb/gal, example for gasoline)6
Fuel flow needed (lb/hr)300
Pump flow needed (L/hr)189
  1. Lb=500×0.5×(1+20100)=300
  2. Gph=3006=50

Pump flow needed (US gal/hr) 50.0

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

What pump flow does a 500 hp engine with BSFC 0.5 need, with a 20% margin?

300 lb/hr, which is 50.0 gallons (189 liters) per hour of gasoline at 6.0 lb/gal.

Why add a margin?

The pump's flow falls with pressure and voltage, and the return line must keep flowing so the regulator can hold pressure.