Skip to content
FiftyCalc Free calculators for all 50 states

Inductive Reactance Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

Find how much an inductor opposes alternating current at a given frequency, in ohms.

Result

Sample figures

Inductive reactance X_L—Ω

Current through an ideal coil (A rms) —

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Inductive Reactance Calculator

Frequency: enter 0 or more. Prefilled example: 60.

Frequency unit

Frequency unit: choose Hz, kHz or MHz. Prefilled example: Hz.

Inductance: enter 0 or more. Prefilled example: 100.

Inductance unit

Inductance unit: choose Henries (H), Millihenries (mH) or Microhenries (µH). Prefilled example: Millihenries (mH).

AC voltage across the coil (V rms, optional): enter 0 or more. Prefilled example: 120.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. Frequency: enter 0 or more.
  2. Frequency unit: choose Hz, kHz or MHz.
  3. Inductance: enter 0 or more.
  4. Inductance unit: choose Henries (H), Millihenries (mH) or Microhenries (µH).
  5. AC voltage across the coil (V rms, optional): enter 0 or more.
  6. Read the result: Inductive reactance X_L; the panel also shows Current through an ideal coil (A rms).

How this calculator works

Inductive reactance X_L = 2π × f × L, where f is the frequency in hertz and L the inductance in henries. It grows in proportion to frequency: an inductor passes DC freely and blocks high frequencies.

For an ideal inductor (no winding resistance), the current is I = V ÷ X_L and lags the voltage by 90°.

The formula

  1. Xl=2×π×f×fu×l×lu
Symbols used in the formula
SymbolMeaningUnit
fFrequency
fuFrequency unit
lInductance
luInductance unit
XlInductive reactance X_LΩ

Worked example

Frequency60
Frequency unitHz
Inductance100
Inductance unitMillihenries (mH)
AC voltage across the coil (V rms, optional)120
Current through an ideal coil (A rms)3.1831
  1. Xl=2×3.14159×60×1×100×0.001=37.6991

Inductive reactance X_L 37.6991 Ω

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

What is the reactance of a 100 mH coil at 60 Hz?

About 37.70 ohms.

Is reactance the same as resistance?

Both are in ohms, but reactance stores and returns energy instead of turning it into heat, and it changes with frequency.