Skip to content
FiftyCalc Free calculators for all 50 states

Wheatstone Bridge Calculator

Test cases replayed : 2 of 2 match · Methodology · No outside source listed

Enter the three known resistors to get the unknown resistance at balance, and an actual Rx with the supply to see the bridge output voltage.

Result

Sample figures

Rx at balance—Ω

Bridge output with the actual Rx (mV) —

Estimate for planning only, not tax, legal, financial or medical advice. This calculator uses the method explained on this page.

Wheatstone Bridge Calculator

R1, top left, in Ω: enter 0 or more. Prefilled example: 100.

R2, bottom left, in Ω: enter 0 or more. Prefilled example: 200.

R3, top right, in Ω: enter 0 or more. Prefilled example: 150.

Supply voltage, in V: enter a number. Prefilled example: 5.

Actual Rx, bottom right (for the output voltage), in Ω: enter 0 or more. Prefilled example: 310.

How to use this calculator

Fill in the fields in this order; each step takes you to its field.

  1. R1, top left, in Ω: enter 0 or more.
  2. R2, bottom left, in Ω: enter 0 or more.
  3. R3, top right, in Ω: enter 0 or more.
  4. Supply voltage, in V: enter a number.
  5. Actual Rx, bottom right (for the output voltage), in Ω: enter 0 or more.
  6. Read the result: Rx at balance; the panel also shows Bridge output with the actual Rx (mV).

How this calculator works

The bridge has two voltage dividers across the same supply: R1 over R2 on the left, R3 over Rx on the right. It is balanced (zero output) when R2 / (R1 + R2) = Rx / (R3 + Rx), that is Rx = R2 × R3 / R1.

Off balance, the output between the two midpoints is V_out = V_s × [Rx / (R3 + Rx) − R2 / (R1 + R2)], positive when the right midpoint is higher. Strain gauges and RTD sensors are read this way.

The formula

  1. Rx=r2×r3r1
Symbols used in the formula
SymbolMeaningUnit
r1R1, top leftΩ
r2R2, bottom leftΩ
r3R3, top rightΩ
RxRx at balanceΩ

Worked example

R1, top left100 Ω
R2, bottom left200 Ω
R3, top right150 Ω
Supply voltage5 V
Actual Rx, bottom right (for the output voltage)310 Ω
Bridge output with the actual Rx (mV)36.2319
  1. Rx=200×150100=300

Rx at balance 300 Ω

Each step uses the unrounded value of the step before it; figures on this page are rounded for display.

Frequently asked questions

Why is a Wheatstone bridge accurate?

At balance no current flows through the detector, so its own resistance and calibration do not affect the result; only the ratio of the known resistors matters.

Does the supply voltage change the balance point?

No. Balance depends only on the resistor ratios; the supply only sets how large the output is off balance.

Related calculators